Functional & Integrated Ceiling Systems

Ventilation Ceiling Panel

HVAC-integrated metal ceiling panel combining diffuser opening, adjustable air damper and plenum box in one body. A2-s1,d0 fire class and any RAL color.

Material EN 10346 DX51D+Z galvanized steel / AA3005 aluminum
Module Sizes 600x600, 600x1200 mm + made to measure
Panel Thickness 0.6 - 0.8 mm
Ventilation Unit Integrated diffuser + adjustable damper + plenum box

Certifications

  • EN 13964
  • EN 13501-1: A2-s1,d0
  • ISO 9001 quality management
  • CE (EU Construction Products Regulation)
Quick Answer

The ventilation ceiling panel is a metal suspended ceiling panel that combines a diffuser opening, adjustable air damper and plenum box in a single body. It delivers HVAC supply and return air without breaking the ceiling's appearance, with EN 13501-1 A2-s1,d0 fire classification and any RAL color for offices, hospitals and educational buildings.

The ventilation ceiling panel is a metal suspended ceiling panel that integrates the HVAC installation into the ceiling plane, with a diffuser opening and air damper built into the panel body. Supply and return air are delivered without breaking the ceiling's visual continuity - no separate diffuser frames or mismatched face plates are needed.

Panel bodies are produced from EN 10346 DX51D+Z galvanized steel or AA3005 aluminum in 0.6-0.8 mm sheet thickness. Standard modules are 600x600 and 600x1200 mm, delivered with edge profiles compatible with clip-in or lay-in carrier systems. Surfaces are powder coated in any RAL color, and diffuser accessories are painted in the same batch for perfect visual matching.

The ventilation unit consists of an integrated round or multi-slot diffuser, an adjustable air damper and a plenum box for flexible duct connection. Top or front connection options accommodate HVAC site tolerances. Return-air panels are produced with perforation patterns reaching 10-20% free area; internal acoustic infill reduces duct noise transmission from the plenum into the room.

For fire safety, the panel and diffuser unit are classified A2-s1,d0 according to EN 13501-1: non-combustible with no flame spread. The panel system is installed on EN 13964-compliant carriers, and cleanroom projects are supported with details in line with ISO 14644-1 classification.

Installation is as fast as a standard metal ceiling: the panel lays or clips into the grid like any other tile; the plenum box above connects to the flexible duct and the damper is balanced at commissioning. The flush diffuser frame does not protrude from the surface, and panels can be removed for easy access to dampers and ducts.

Applications include offices and meeting areas, hospitals and polyclinics, educational buildings, hotels, airport halls, food and pharmaceutical production areas, and data center support rooms. Typical lead time is 2-4 weeks; diffuser selection and panel layout are planned together with your HVAC design based on air volume rates.

Material EN 10346 DX51D+Z galvanized steel / AA3005 aluminum
Module Sizes 600x600, 600x1200 mm + made to measure
Panel Thickness 0.6 - 0.8 mm
Ventilation Unit Integrated diffuser + adjustable damper + plenum box
Perforation / Free Area 10 - 20% free area on return-air panels
Acoustic Performance Internal acoustic infill reduces duct noise
Fire Classification EN 13501-1: A2-s1,d0
Installation System Clip-in or lay-in T-grid carrier
Weight Approx. 3.0 - 5.0 kg/m² incl. diffuser
  • Offices and meeting rooms
  • Hospitals and polyclinics
  • Schools and universities
  • Hotels and conference centers
  • Food and pharmaceutical production areas
  • Data center and technical rooms
  • Integrated diffuser panels for HVAC supply and return air
  • Commissioning flexibility with adjustable air damper
  • Return-air panel options with 10 - 20% free area
  • EN 13501-1: A2-s1,d0 non-combustible class
  • Any RAL color with color-matched diffuser accessories
  • Compatible with clip-in and lay-in carrier systems
  • Removable panel for easy damper and duct maintenance

Installation & Application

  1. 1 Ceiling level is set out and the carrier grid is installed in coordination with HVAC crossings.
  2. 2 Ventilation panel positions are marked on the grid according to the HVAC layout.
  3. 3 The flexible duct is connected to the plenum box, clamped and checked for airtightness.
  4. 4 The panel is laid or clipped into the grid like any other tile; the diffuser frame is aligned flush.
  5. 5 Return-air panels are placed with the required free area patterns.
  6. 6 Dampers are balanced at commissioning and air volumes are measured before handover.

FAQ

Panel bodies are produced from EN 10346 DX51D+Z galvanized steel or AA3005 aluminum in 0.6-0.8 mm thickness; the diffuser unit and accessories use the same coated metal system.

Standard modules are 600x600 and 600x1200 mm; custom sizes are produced to match your existing grid. Typical lead time is 2-4 weeks; the exact delivery date is stated in the quotation according to project scope.

The panel and diffuser unit are classified A2-s1,d0 according to EN 13501-1: non-combustible, no flame spread, no flaming droplets. The carrier system complies with EN 13964.

Room-based air volume rates from your HVAC design are used as the basis; diffuser type (round or slot), size and damper range are selected accordingly. Panel layout is coordinated with the mechanical contractor together with the grid modulation.

The coated metal surface is wiped with a damp cloth; the panel is released from the grid in one motion to access the damper mechanism and plenum. Periodic filter and damper checks are part of routine HVAC maintenance.

Panels and diffuser accessories are painted in the same batch in any RAL color, so no color or texture mismatch appears on the ceiling. Sample approval is made for large projects.