Paneele modulare de tavan metalic

Panou de tavan metalic tip scândură

Suprafață de tavan modernă, curată și continuă, cu panouri late de 100–300 mm, în bucăți unice de până la 6 m.

Material AA3005/AA3105 aluminum or DX51D+Z galvanized steel
Plank Width 100 / 150 / 200 / 300 mm
Panel Length Single piece up to 6000 mm
Panel Thickness 0.5–0.8 mm steel; 0.6–1.0 mm aluminum

Certificări

  • EN 13964
  • EN 13501-1: A2-s1,d0
  • ISO 9001 quality management
  • CE (EU Construction Products Regulation)
Răspuns scurt

The plank metal ceiling provides a clean, continuous suspended surface with planks 100–300 mm wide and single-piece lengths up to 6 m. Perforated planks with acoustic fleece reach NRC 0.75, with any RAL or wood-look finish and A2-s1,d0 fire class; production typically takes 2–4 weeks.

The plank metal ceiling system is a clean, continuous suspended ceiling solution formed by side-by-side wide-format strips — from 100 to 300 mm — produced as cassette (box plank) or flat profiles. Compared to linear ceilings it delivers a wider, tighter appearance, providing a clean architectural backdrop for offices, hospitals and educational buildings.

Panels are produced from AA3005/AA3105 aluminum or DX51D+Z galvanized steel (EN 10346) in 0.5–1.0 mm gauges, with single-piece lengths up to 6000 mm. Any RAL shade of powder coating, anodizing or wood-look lamination can be applied, and matte, satin and gloss options can be mixed within one design. The box plank profile provides higher body stiffness and a crisper seating than flat panels.

Where acoustics are needed, linear-perforated planks combined with acoustic fleece achieve NRC 0.55–0.75 absorption (ASTM C423), controlling reverberation in open offices and meeting areas. All components reach fire class A2-s1,d0 under EN 13501-1 and the system complies with the EN 13964 suspended ceiling standard.

Installation uses a clip-on concealed spring carrier: planks can be removed and refitted one by one, keeping every service point reachable. Carriers are levelled on an ASTM C635 compliant suspension; wall angles and finishing trims are produced in the same surface code. Linear luminaires and air diffusers align with the plank lines.

The maintenance-free, moisture- and corrosion-resistant surface keeps its as-new look for years. Open and cellular offices, hospital and clinic corridors, schools, hotel room corridors, retail areas and wide-span halls or terminals are typical applications. Production is typically completed within 2–4 weeks.

Material AA3005/AA3105 aluminum or DX51D+Z galvanized steel
Plank Width 100 / 150 / 200 / 300 mm
Panel Length Single piece up to 6000 mm
Panel Thickness 0.5–0.8 mm steel; 0.6–1.0 mm aluminum
Surface Finish RAL powder coating, anodized, wood-look; matte / satin / gloss
Acoustic Performance NRC 0.55–0.75 (perforated planks + acoustic fleece)
Fire Classification EN 13501-1: A2-s1,d0
Installation System Concealed spring carrier, plank-by-plank demountable
Weight 2.8–5.0 kg/m²
  • Open-plan and cellular offices
  • Hospital and clinic corridors
  • Schools and university buildings
  • Hotel room corridors
  • Retail store areas
  • Wide-span halls and terminals
  • 100–300 mm width options for a clean, continuous surface
  • Single-piece planks up to 6000 mm
  • Box plank profile for high body stiffness
  • NRC up to 0.75 with perforated planks and acoustic fleece
  • Any RAL powder coating, anodized and wood-look finishes
  • Plank-by-plank demountable mounting with full service access
  • Aligned integration with linear lighting and diffusers
  • EN 13501-1 A2-s1,d0 fire class and EN 13964 compliance

Instalare și aplicare

  1. 1 Plank direction and the carrier axis are defined in the layout plan.
  2. 2 Hanger wires and ASTM C635 compliant carrier rails are set and levelled.
  3. 3 Wall angle profiles are fixed along the perimeter.
  4. 4 Planks are clipped onto the spring carriers starting from the wall; joints are aligned.
  5. 5 Linear luminaires and diffusers are aligned with the plank lines.
  6. 6 Level, joint and surface checks complete the installation.

Întrebări frecvente

Lamelele sunt produse din aluminiu AA3005/AA3105 sau oțel galvanizat DX51D+Z (EN 10346) în grosimi de 0,5-1,0 mm; toate componentele sunt de clasă de foc A2-s1,d0.

Lățimile standard sunt 100, 150, 200 și 300 mm cu lungimi într-o singură bucată de până la 6000 mm. Profilul de lamelă cutie de 300 mm este recomandat acolo unde este necesară o rigiditate mai mare.

Toate componentele sunt clasificate A2-s1,d0 conform EN 13501-1; sistemul purtător este conform cu ASTM C635, iar sistemul este compatibil cu EN 13964.

Da. Lamelele cu perforație liniară combinate cu manta acustică ating absorbție de NRC 0,55-0,75 (ASTM C423), contribuind la controlul reverberației în birourile deschise.

Suprafața acoperită se șterge cu o cârpă umedă; revopsirea nu este necesară. Deoarece lamelele se demontează individual, instalațiile sunt ușor accesibile, iar o lamelă deteriorată poate fi înlocuită separat.

Pot fi aplicate laminat cu aspect de lemn, anodizare și orice nuanță RAL. Producția durează de obicei 2-4 săptămâni în funcție de amploarea proiectului.