Funkcjonalne i zintegrowane systemy sufitowe

Klapa rewizyjna sufitu

Klapy rewizyjne z ukrytymi zawiasami zapewniające szybki i bezpieczny dostęp serwisowy do przestrzeni instalacyjnej; drzwi stalowe A2-s1,d0 w dowolnym kolorze RAL.

Material DX51D+Z Galvanized Steel (0.8 - 1.2 mm); aluminum option
Standard Sizes 300x300, 450x450, 600x600, 600x900, 600x1200 mm
Leaf Thickness 0.8 - 1.2 mm
Surface Finish RAL Powder Coating or paint-ready galvanized

Certyfikaty

  • EN 13964
  • EN 13501-1: A2-s1,d0
  • EN 13501-2 fire-rated versions (EI 30 - EI 120)
  • ISO 9001 quality management
  • CE (EU Construction Products Regulation)
Krótka odpowiedź

The ceiling access panel is a steel door with concealed spring hinges and locking options that provides fast, safe maintenance access above suspended ceilings. Standard sizes up to 600x1200 mm, any RAL color, and fire-rated versions EI 30 - EI 120 per EN 13501-2 are available.

The ceiling access panel is a functional element providing scheduled maintenance access to the service volume above the suspended ceiling — dampers, valve groups, electrical panels, fan-coil units and fire systems. With concealed spring hinges and optional locking systems, it forms an almost invisible door that aligns flush with the surrounding ceiling modules.

Frame and door leaf are manufactured from EN 10346 DX51D+Z galvanized steel, 0.8 - 1.2 mm thick, with an aluminum option. Standard sizes of 300x300, 450x450, 600x600, 600x900 and 600x1200 mm are supplemented by custom fabrication. Locking options include spring latches, quarter-turn latches, cylinder key locks and touch latches; a safety drop-chain is added where public safety is required.

The body meets EN 13501-1 class A2-s1,d0; where the service penetration must not compromise fire barriers, versions rated EI 30 - EI 120 per EN 13501-2 are available. Perimeter-gasket versions limit plenum noise transfer, and washable, sterilization-resistant surface options serve hygienic volumes.

Installation is lay-in or clip-in to T-grid systems, plaster-in bead framing inside gypsum partitions, or direct fixing to structural supports. Frame types include flush, plaster-bead and perimeter-gasket variants. Surfaces are powder coated in any RAL tone or supplied paint-ready galvanized.

Typical applications include office and mall corridors, hospital and laboratory volumes, hotel service axes, airport and metro ceilings, industrial facilities and food-hygiene zones requiring washable surfaces. Panels are positioned 1:1 above each service requiring access.

Metaltavan manufactures standard and custom access panels with 30 years of experience and regular exports to 7 markets. Typical production lead time is 2 - 4 weeks. Surfaces wipe clean with a damp cloth; an annual check of hinges and locks is sufficient.

Material DX51D+Z Galvanized Steel (0.8 - 1.2 mm); aluminum option
Standard Sizes 300x300, 450x450, 600x600, 600x900, 600x1200 mm
Leaf Thickness 0.8 - 1.2 mm
Surface Finish RAL Powder Coating or paint-ready galvanized
Locking Spring latch, quarter-turn, cylinder lock, touch latch
Fire Classification A2-s1,d0; fire-rated EI 30 - EI 120 (EN 13501-2)
Installation Lay-in / clip-in T-grid, plaster-in or direct fixing
Weight 1.5 - 6 kg per panel
  • Office and shopping mall corridors
  • Hospital and laboratory volumes
  • Hotel service corridors and above-room services
  • Airport and metro ceilings
  • Industrial maintenance axes
  • Food and hygiene zones (washable version)
  • Almost invisible door flush with the ceiling via concealed spring hinges
  • Standard sizes up to 600x1200 mm plus custom fabrication
  • Spring latch, quarter-turn, cylinder lock and touch latch options
  • Fire-rated versions EI 30 - EI 120 per EN 13501-2
  • Perimeter gaskets limit plenum noise transfer
  • Any RAL powder coating or paint-ready galvanized finish
  • One frame family for T-grid, drywall and direct fixing
  • Safety drop-chain for public areas

Instalacja i zastosowanie

  1. 1 Mark service points on a 1:1 layout plan and determine panel sizes.
  2. 2 In T-grid systems, seat the frame lay-in or clip-in; in drywall, position the plaster-in frame with its bead.
  3. 3 Adjust the frame level so joints align with surrounding ceiling modules.
  4. 4 Hang the door leaf on concealed spring hinges and mount the locking mechanism.
  5. 5 Fit gaskets and the safety drop-chain where required.
  6. 6 Test opening and closing; remove surface protection at handover.

Częste pytania

Rama i skrzydło wykonane są ze stali ocynkowanej EN 10346 DX51D+Z o grubości 0,8–1,2 mm; na życzenie dostępna jest wersja aluminiowa.

Standardowe to 300x300, 450x450, 600x600, 600x900 i 600x1200 mm, a każdy rozmiar specyficzny dla projektu może zostać wyprodukowany.

Tak. Standardowy korpus ma klasę A2-s1,d0; tam, gdzie przejścia instalacji nie mogą naruszać przegród przeciwpożarowych, oferowane są wersje w klasie EI 30 - EI 120 wg EN 13501-2.

Tak. Istnieją detale do profili T lay-in lub clip-in, ramy zabudowane w płytach gipsowo-kartonowych oraz mocowanie bezpośrednie do podkonstrukcji betonowych lub stalowych.

Powierzchnie malowane proszkowo czyści się wilgotną szmatką; w strefach higienicznych preferowane są powierzchnie zmywalne. Wystarczy coroczna kontrola zawiasów i zamków.

Nakładamy malowanie proszkowe w każdym tonie RAL. Typowy czas produkcji to 2–4 tygodnie; dla rozmiarów niestandardowych harmonogram zależy od ilości i detalu.